Frenic Mega
Frenic Eco
Fernic Multi
Fernic Mini
Fernic HVAC
Fernic Aqua
FVR Micro
Frenic 4600FM5E
Frenic Lift
Frenic Multi LM
-
Frenic Mega
Overload durability: 200% For 3 sec, 150% for 1Min (HD model) 120% for 1min (LD model).
Ideal for highly accurate control
Original Dynamic torque vector control
quick reaction to fluctuation of imapct load
cutomize logic built in
Ambient Temp : 50 Degree C.
3 Analog inputs / 2 Analog outputs.
9Digital inpiuts
2 relay outputs / 4 transistor outputs.
-
Frenic Eco
Equipped with the optimum functions for HVAC.
Dynamic rotation of Pump Motors.
Ambinet Temp: 50 Degree C.
Long life design.
3 Analog inputs (Including Potentiometer).
7 Digital Inputs (Including FWD/REV).
2 Analog Outputs.
2 Relay outputs.
3 Transistor Outputs.
-
Fernic Multi
Overload durability: 200% for 0.5 sec, 15% for 1 Min.
Highest Standards of Control and performance in its class.
Optimum for the operations specific to vertical and horizontal conveyance.
Simple operation & Simple Connection.
Rated Temp: 50 Degree C.
2 Analog inputs.
7 Digital Inputs.
1 Analog Output.
1 Relay output.
2 Transistor Outputs.
-
Fernic Mini
High Starting Torque at 150% /200% overload
For 0.5 Seconds.
Built in Braking Chopper.
Stable Operation at low speed.
Ambient Temp: 50 Degree C.
Built in PlD Control Function.
Non Linear V/F Pattern
Component Life Time forecast. -
Fernic HVAC
EMC filter (C2 Class).
DC Choke built in as standard feature.
Slim Body, IP21 (Standard) Enclosures/ same dimension for IP55/IP21.
4-PID control.
Wet bulb temperature presumption function.
Fire mode (Force protection).
Pickup Operation function.
Real time clock.
Torque Vector control.
Filter clogging prevention function.
Customize logic.
2 Level Password function.
LCD Keypad.
Standard Communications: BAC net, Modbus RTU, Metasys N2. -
Fernic Aqua
EMC filter (C2 Class).
DC Choke built in as standard feature.
Slim Body, IP21 (Standard) Enclosures/ same dimension for IP55/IP21.
4-PID control.
Wet bulb temperature presumption function.
Fire mode (Force protection).
Pickup Operation function.
Real time clock.
Torque Vector control.
Filter clogging prevention function.
Customize logic.
2 Level Password function.
LCD Keypad.
Standard Communications: BAC net, Modbus RTU, Metasys N2. -
FVR Micro
High Starting Torque of 150% or more.
Stable operation at low speed.
Wobulation & Pattern Operation.
Nonlinear V/f pattern.
Ambient Temp: 50 Degree C.
Built in R8485 Communication as standard.
Frequency setting potentiometer as standard. 6 Alarms history. -
Frenic 4600FM5E
Multi Pulse Full Wave Rectifier Comply IEEE519 Guidelines (THD<5%).
No requirement of Input Harmonics Filter
No requirement of Output Sine Wave Filter
Snubberless design.
Sine Wave output Voltage & Current Waveform.
Low Voltage surge: patented 3 Level IGBT Cell.
Maintenance free Dry type Air cooled Transformer
Web adaptor for operation monitoring
Non Synchronous / Synchronous Bypass system possible
-
Frenic Lift
Optimum Exclusive design for Passenger Elevators.
PMSM (Gearless) / IM Common drive.
200% Overload capacity for 10 seconds.
High performance vector control.
PG feedback for IM close loop operation.
Maintenance functions] long design life.
Supports 48 V DC / 200 V AC 1-Ph for ARD operation.
Starting without Load Cell.
Creep less 8: short floor Functions -
Frenic Multi LM
200 % OL for 3 Sec, 150 % OL for 60 Sec.
Ideal design for open loop elevator application.
6 S- Curves for smooth operation of elevator.
Supports 200 V 1- PH ARD operation as standard feature.
External break logic control by drive.
Output contactor control by digital output and built in timer Function.
Customizable 4— point V/F pattern.
Breaking resistor overload protection.
PTC Input With threshold settable